Click on “download now” to proceed with the download of the update file.
XFIRE
Fire Control Panel
Version: r110a26
Date: 19/11/2024
Note:
Updates must be loaded from the PC software settings.
Update details:
– network clock synchronisation function
– inserted control that prevents duplication of fault events (in the remote control unit with respect to the source)
XFIRE SOFT
Software PC
Version: 1.0.02b01
Date: 19/11/2024
Note:
XFIRE-SOFT needs to be downloaded only once,
updates can be performed directly from the program.
Download drivers for windows 7 and 8.
Download drivers for windows 7 and 8.
Version: 1.0.02b01
Date: 19/11/2024
Note:
XFIRE-SOFT needs to be downloaded only once,
updates can be performed directly from the program.
Update details:
– improved graphic display
– parameter for enabling XFIRE’s network clock synchronisation inserted
– revision of dialer configuration
XFIRE LCD
Remote Panel
Version: r110a26
Date: 19/11/2024
Note:
FIRMWARE XFIRE-WEB
Version: r100b2
Date: 17/10/2024
Note:
To be paired with the XFIRE control unit with firmware r110a24 or later.
Procedure for Updating the eweb Board
- Ensure that the control panel is updated to version 1.00a24 or later.
- Configure the network parameters in the control panel.
- Using a browser connected to the network where the eweb is located, access
http://ip_address/swupgrade
, whereip_address
is the address configured or provided by the DHCP server. - Click “select file” and enter the name of the update bim file.
- Click “upload” and wait for the operation to complete, which may take a few minutes. The browser may not respond during this operation; during this time, only the E LED will be flashing on the board.
- The completion of the operation is indicated by the red A LED being lit.
Meaning of LEDs on the Board
- A (solid red): the board has completed the startup phase and is operational.
- B (solid green): active Ethernet link.
- C (solid green): the board is communicating with the control unit.
- C (flashing green): the board is connected to a 485 bus, but the control unit is not querying it.
- D (solid green): the board is in a temporary phase of handling programming change; at the end of this phase, it will reset.
- E (flashing green, other LEDs off): the board is receiving a software update, after which it will restart.
- E (flashing green, A LED lit): at least one client is connected, but no user has validated.
- E (solid green, A LED lit): at least one client is connected, with a validated user.
Under normal conditions, the LEDs A, B, and C are lit solidly; the E LED indicates active external connections.
In case of inability to access the configured address (point 3), choose one of the following alternatives:
- From a compatible network, use the address 10.2.200.25/24.
- By moving DIP switch 1 to ON, force access to the DHCP server.
- By moving DIP switch 2 to ON, force the address 192.168.1.67/24.
When the browser accesses the “swupgrade” page (point 3), follow the indicated procedure. After the update is complete, return the DIP switches to OFF; the updated board will follow the configuration of the control unit.
FIRMWARE XFIRE-CTG4
Version: 10p9
Date: 17/10/2024
Note:
To be paired with the XFIRE control unit with firmware r110a24 or later.
Drivers to update the XFIRE-CT G4
SOFTWARE SAGITTARIUS
Version: 13.00.00
SOFTWARE TAURUS
Version: 13.00.00